SC No. Level Error Name/Error Condition/Major Cause/Solution
SC653-00 D
Incorrect remote service ID2
ID2 stored in the NVRAM has either of the following problems.
Number of characters is not 17.
Includes a character that cannot be printed.
All spaces
NULL
Replace the NVRAM.
Clear the RC Gate install status, write the common certificate, and then
begin installation again.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC670-00 D Engine start up error
Case 1
/ENGRDY signal was not asserted when the machine was
turned on or returned from energy saver mode.
/IPURDY signal was not asserted when the machine was
turned on or returned from energy saver mode.
EC response was not received within specified time from power
on.
PC response was not received within specified time from power
on.
SC response was not received within specified time from power
on.
Writing to Rapi driver failed (the other party not found through
PCI).
Case 2
Unexpected down status was detected after /ENGRDY
assertion.
Case 1
Engine board does not start up.
Case 2
Engine board reset unexpectedly.
Service Call 620-689
535