SC No. Level Error Name/Error Condition/Major Cause/Solution
SC653-00 D
Incorrect remote service ID2
ID2 stored in the NVRAM has either of the following problems.
• Number of characters is not 17.
• Includes a character that cannot be printed.
• All spaces
• NULL
Replace the NVRAM.
Clear the RC Gate install status, write the common certificate, and then
begin installation again.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC670-00 D Engine start up error
• Case 1
• /ENGRDY signal was not asserted when the machine was
turned on or returned from energy saver mode.
• /IPURDY signal was not asserted when the machine was
turned on or returned from energy saver mode.
• EC response was not received within specified time from power
on.
• PC response was not received within specified time from power
on.
• SC response was not received within specified time from power
on.
• Writing to Rapi driver failed (the other party not found through
PCI).
• Case 2
• Unexpected down status was detected after /ENGRDY
assertion.
• Case 1
• Engine board does not start up.
• Case 2
• Engine board reset unexpectedly.
Service Call 620-689
535