SC No. Level Error Name/Error Condition/Major Cause/Solution
The HDD is connected but the driver detected the following errors.
SS_NOT_READY:/* (-2)HDD does not become READY*/
SS_BAD_LABEL:/* (-4)Wrong partition type*/
SS_READ_ERROR:/* (-5)Error occurred while reading or
checking the label*/
SS_WRITE_ERROR:/* (-6)Error occurred while writing or
checking the label*/
SS_FS_ERROR:/* (-7)Failed to repair the filesystem*/
SS_MOUNT_ERROR:/* (-8)Failed to mount the filesystem*/
SS_COMMAND_ERROR:/* (-9)Drive not responding to
command*/
SS_KERNEL_ERROR:/* (-10)Internal kernel error*/
SS_SIZE_ERROR:/* (-11)Drive size too small*/
SS_NO_PARTITION:/* (-12)The specified partition does not
exist*/
SS_NO_FILE:/* (-13)Device file does not exist*/
Attempted to acquire HDD status through the driver but there has
been no response for 30 seconds or more.
Unformatted HDD
Label data corrupted
HDD defective
Format the HDD through SP mode.