SC No. Level Error Name/Error Condition/Major Cause/Solution
SC914-00 B
External Controller Error 5
Notification from external application (external controller)
Subject to external application (external controller) specification
Turn the main power off/on.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC915-01 A External Controller Error 6 (Egret board error)
SC915-02 A External Controller Error 6 (HDD serial communication error)
SC915-03 A External Controller Error 6 (CPU temperature rise)
SC915-04 A
External Controller Error 6 (Unable to communicate with GW controller
because invalid command was received)
SC915-05 A
External Controller Error 6(Unable to communicate with GW controller
because of an error)
Notification from external application (external controller)
Notification from external application (external controller)
Replace the Egret controller board.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC919-00 D
External controller down
While EAC (External Application Converter), the conversion
module, was operating normally, the receipt of a power line
interrupt signal from the FLUTE serial driver was detected, of
BREAK signal from the other station was detected.
External controller and the machine had been operating correctly (*) but
the external controller was turned off or rebooted, or the video bus was
disconnected.
* Printing or scanning using the external controller.
Turn the main power off/on.