SPIROR HP - DR
Allowed pressure
(max)
bar 10
Average air
consumption
Nl/min 20
T
he table below shows the technical s
p
ecifications of the machine (Spiror DR).
Description Units
of
measur‑
ement
Value
Machine Spiror DR 400 Spiror DR 600 Spiror DR 900
Supply voltage 230V 3Ph 50/60Hz (upon request)
400V 3Ph + N 50/60Hz
Installed power kW 2,2/2,6
Absorption A 12/13,5
Electrical system
protection
IP54
Rotating ring
speed (max)
rpm 220 180 130
Product infeed
speed (max)
m/min 80 60 50
Product infeed
speed (min)
m/min 20 16 10
Total weight kg 700 800 900
Worktable height mm 800
Operating
pressure
bar 6± 1
Allowed pressure
(max)
bar 10
Average air
consumption
Nl/min 20
3.7.1.PRODUCT SIZE
T
he dimensions (width and height or diameter) of the products’ cross sections workable on each machine must
remain within the respective diagrams; the same is to be said for the cross sections that are uniform on all the
product’s length.
For best results from a qualitative point of view, the rotating ring diameter must be the smallest possible,
compared to the product’s cross section.
For cross sections smaller than those indicated, contact the manufacturer.
For products that intersect the sketched areas, contact the manufacturer.
|
Important
T
he maximum indicated length is obtained by taking into account the lateral pneumatic guides.
For different guides, contact the Manufacturer.
|
Important
Lengths and workable cross sections in each type of machine must previously be defined with the
manufacturer.
T
he minimum working length i
s
800 mm for the HP model and 1000 mm for DR.