SPIROR HP - DR
3.8. SURROUNDING AREAS
) Operator's working area.
B) Product outfeed area
(∗)
.
C) Product infeed area
(∗)
.
D) Sorrounding area.
(∗)
These areas must be suitably sized to
the product being processed.
3.9. NOISE LEVEL
While working, the machine reaches the noise levels shown in the table.
Acoustic power measured during working according to:
UNI EN ISO 3744
EN ISO 11201
Description
verage level of
ressure on the
measurement surface
(Lpm)
coustic power
output (Lw)
Level at the
operator's place
(Lop)
Functioning in
working conditions
71,4 dB (A) 88,6 dBw (A) 70,9 dB (A)
Danger - Warning
Prolonged exposure over 80 dB (A) may cause health problems. The use of appropriate protection systems is
recommended (headphones, ear plugs, etc.).
3.10. INSTALLATION ENVIRONMENT CHARACTERISTICS
Careful consideration must be given to the place where the machine is to be installed, in order to ensure that
it may be easily operated, without creating any unnecessary risks for personnel. Therefore we suggest the
following prerequisites:
Room temperature of between 5 °C and 40 °C.
Suitable air exchange to ensure adequate comfort for the operator.
Lighting of the work environment that guarantees adequate comfort to the operator who is using the
machine.
Space around the machine as indicated in the figure.
Floor surface with adequate payload for the weight to support.
he area must be equipped with a power supply socket and a compressed air supply socket.