SPIROR HP - DR
9.3. REPLACE ROTATING RING
BELT
1. Slacken the belt (A).
2. Remove the belt from its housing.
3. Insert the new belt.
4. tighten the belt (See "Rotating Ring Belt
- Adjustment").
9.4. FUSE REPLACEMENT
Note
Work that must be performed mandatorily by a
specialised operator.
he fuses are located inside the control panel
and are reachable by opening the door with
proper access keys.
Rotate main switch in position "0" (off) before
going inside the compartment.
Refer to wiring diagram supplied along with the
machine.
Danger - Warning
Make sure that the amperage of the new fuse is
the same as that of the one to be replaced.
Danger - Warning
Do not bring in water, oil or dirt inside the
electric panel.
Danger - Warning
When closing the door, be careful not to damage the cables and wiring.
9.5. LIST OF ESSENTIAL SPARE PARTS
List of the spare parts of easy wear and of which it would be necessary to have available to avoid long
operation stops of the machine.
For ordering, contact your local Dealer and refer to the spare parts catalogue.
‒ Cutting blade.
Important
Replace the worn parts with original parts.
Use the oils and greases specified in the manual. All these measures may guarantee the expected operating
and safety level of the machine.