R&S PR100 User Manual
10.5.2.3 Memory Scan Mode MSCAN
Memory Scan Mode shows exactly the same behaviour as the Frequency
Scan Mode in the way of internal states as presented in Figure 4.
10.5.2.4 Panorama Scan Mode PSCAN
In Panorama Scan Mode only states Stopped and Running are applicable.
11 Commands Reference
This chapter describes the SCPI commands that are specific to the Orion MR
product. They are additional to the list in Chapter 4 of [Orion SCPI].
11.1 Common Commands
The commands listed in this section are taken from the IEEE 488.2 (IEC 625-
2) standard and are supported by all instruments. However each instrument
type may respond differently, e.g. the option query comannd returns all
installed options which might be instrument specific.
*OPT?
OPTION IDENTIFICATION QUERY queries about the options in the unit and
outputs a list of installed options. The options are seperated by a comma. The
returned optionlist is fixed and options which are not installed have a value
equal to zero. Installed options are indicated by having the abbreviation used
in the optionlist below:
Panorama Scan PS
Remote Control RC
Fieldstrength Measurement FS
Example:
*OPT? returned PS,0,RC,0,FS,0,0
This instrument has the following options installed:
Panorama Scan
Reserved
Remote Control
Reserved
Fieldstrength Measurement
Reserved
Reserved