R&S PR100 User Manual
[SENSe]
. :GCONtrol
. . :MODE?
Query of type of gain control.
Parameters:
none
Result:
FIX, AUTO
Example:
GCONtrol:MODE? -> AUTO
11.14.1 Sense Memory Scan subsystem MSC
The MSCan system controls the memory-scan function of the device,
provided the memory scan has been activated by SENSe:FREQuency:MODE
MSCan. Each scan is started by INITiate[:IMMediate]. The memory locations
are placed in the MEMory subsystem and are set for query during the scan.
[SENSe]
. :MSCan
. . :CHANnel <mem_loc>|UP|DOWN|NEXT
Setting of current memory location. During the memory scan, this command is
not permitted and generates error -200 , “Execution error”
Parameters:
<mem_loc> memory location in the range [0...1023]
UP|DOWN the next or previous memory location
NEXT the next free memory location is selected, starting from and
including the current location.
If the end of the memory list is reached without finding a free
location, the search continues
at the beginning of the list. If no free location is available an error
-223 “Too much data” is
generated
Example:
MSCan:CHANnel 357
[SENSe]
. :MSCan
. . :CHANnel?
Output of current memory location.
Parameters:
none

Table of Contents