R&S PR100 User Manual
MEMory
. :CONTents? <mem_loc>
Query of contents of memory location.
Parameters:
<mem_loc> CURRENT|0...1023|RX
Result:
Depending on the setting by the command FORMat:MEMory, either ASCII or
binary data are output. See MEM:CONT command for the format
specifications.
Depending on the setting by the command FORMat:BORder, the data are
either big- or little-endian.
Remark:
The parameter <ACT> is not defined for the RX location. However, it is output,
so it should be ignored.
When trying to read out an empty memory location, error -292 ("Referenced
name does not exist") is generated.
Example:
MEMory:CONTents? 1 -> 98500000,30,FM,300,10,0,0,1,0,1
MEMory
. :CONTents
. . :MPAR <mem_loc>,<Boolean>
Setting the memory location parameter <ACT> (MPAR = Memory
PARameter).
Parameters:
<mem_loc> CURRENT|0...1023|NEXT
<Boolean> include/exclude the memory in a memory scan: 0 = OFF, 1 = ON
Example:
MEMory:CONTents:MPAR 1, OFF