Confidential
Chapter 1 Before Installation
RFV01U-D2A Installation Manual v2.0 10
Copyright © 2017, All Rights Reserved.
No. Name Specification Purpose of use
25 Optical Transceiver Removal
Tool
Normal Separate the optical module.
26 Multi tester
Digital Pocket Tester
The voltage and current
measurements.
Whether measured cable
disconnection.
27 Fiber Optical Test Set
Wave length: 1310 nm, 1550
nm (single mode) 850 nm,
1310 nm (multi-mode)
Optical level check.
28 Angle Meter
Normal Antenna angle measurement.
29
Multi master (VSWR and RF
Power)
Normal Feeder VSWR measurement.
30 Compass
Normal Check azimuth during installation.
The required installation tools may vary depending on the conditions at the site.
In addition to the basic tools, a protractor, ladder, safety equipment, cleaning tools,
and so on should also be arranged in consideration of the site conditions.