EasyManua.ls Logo

Santec SNC-3302 - Page 98

Santec SNC-3302
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User manual
SANTEC IP cameras
_________________________________________________________________________________
- 98 -
Security Name:
The max. length of the security name is 32 digits (A-Z, a-z, 0-9).
The following special characters are valid: ! # $ % & ´- . @ ^_ ~
Authentication Type:
2 authentication types are available: MD5 and SHA.
Select SHA as the more secure authentication method.
Authentication Password:
The authentication password must be at least 8 digits long (A-Z, a-z, 0-9). They
will be displayed as dots for security reasons.
The following special characters are valid: ! # $ % & ´- . @ ^_ ~
Encryption Type:
2 encryption types are available: DES and AES.
Select AES as the more secure method.
Encryption Password:
The encryption password must be at least 8 digits long (A-Z, a-z, 0-9). They will
be displayed as dots for security reasons.
The following special characters are valid: ! # $ % & ´- . @ ^_ ~
Note:
The encryption password may also be left blank. However, this means that the
messages will not be encrypted.
Traps for SNMP v1 / v2:
Traps are used by the IP camera to send massages to a management system for important
events or status changes.
Enable traps:
Check the box to activate trap reporting.
Note:
Traps can only be activated, if at least one SNMP function has been activated
before (v1, v2 and/or v3).
Trap address:
Enter the IP address of the management server.
Trap community:
Enter the community to use when sending a trap message to the management
system.
Trap Option: Warm start:
A warm start SNMP trap signifies that the SNMP device, i.e. the IP camera, performs a
software reload.
Click on <Save>.