01:03-02
©
Scania CV AB 2011, Sweden
95
Check whether the connecting rod is twisted
with the indicator studs horizontal.
Checking whether the connecting rod is twisted.
Check whether the connecting rod is bent with
the indicator studs vertical.
Checking whether the connecting rod is bent.
The distance between the indicator studs on the
tool illustrated here is 75 mm. The distance
between one of the indicator studs and the
measuring surface must be max. 0.1 mm when
measured using this tool. Check with a feeler
gauge.
Also check whether the connecting rod is bent in
an S-shape. This is done by measuring the
distance between the outside of the connecting
rod bush and the level surface of the tool. Turn
the connecting rod around and measure the
corresponding distance. The deviation must not
be greater than 0.6 mm.
Checking whether the connecting rod is bent in
an S-shape