77
SensusRF gateway user manual
| 29/10/2019
16.5 “signal” command
The signalcommand returns information to help with diagnostics of the state of communications with the
gateway. Displays the current temperature and maximum temperature reached by the module among others
information. The syntax to send the command is:
signal
Returns:
Where:
Information
Meaning
SIRT 1C9C794
Gateway SiRT radio serial number
18032021141206
Date and time
S(10)
General state of the sensors
GPRS: [0-3]/[0-1]
See description below on the general state of the GPRS
-61dBm
GPRS signal level (from -51dBm to -113 dBm)
TEMP: 31 degrees
temperature in Celsius degrees
The state of GPRS connection is given by the indicators [0-3] / [0-1] representing:
[0-3] - Instantaneous state of connection to the server
0 = not connected
1 = performing input on GPRS network
2 = in process of authentication with the server