8
Service
Description of status and operating displays
Operating Instructions – MOVIMOT
®
advanced
139
8.6 Description of status and operating displays
8.6.1 LED displays of the binary control
The following figure shows the LEDs of the binary design:
DBC10A-0020-503-A-000-000
Binary
DRIVE
[1]
18014427523368971
[1] "DRIVE" status LED
8.6.2 General LEDs
"DRIVE" status LED
LED Operating status/ Meaning Measure
Fault
code
Subfault code
–
Off
Not ready for operation Line voltage absent. Switch on the line
voltage.
Yellow
Flashes very rap-
idly, 4Hz
Not ready for operation Initialization phase Wait for the initializa-
tion to be completed.
Yellow
Flashes 1Hz
Ready but unit inhibited The "STO" signal is active. Deactivate the
"STO” signal.
Yellow
Flashes slowly,
0.5Hz
Ready for operation, but
manual mode/local mode,
device inhibited
Line voltage is OK. –
Yellow
Flashes rapidly,
2Hz
Ready Deactivation of DynaStop
®
without drive enable is active.
–
Yellow
Steady light
Ready but unit inhibited Line voltage is OK.
The output stage is locked.
–
25891936/EN – 05/2020