EasyManuals Logo

SEW-Eurodrive MOVIMOT advanced DRN DBC Series User Manual

SEW-Eurodrive MOVIMOT advanced DRN DBC Series
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #138 background imageLoading...
Page #138 background image
8
Service
Resetting fault messages
Operating Instructions – MOVIMOT
®
advanced
138
Fault Description Index
no.
Possible fault response
Encoder – warning Here you can set the device re-
sponse to an encoder warning.
8622.13
Warning
Application stop (with out-
put stage inhibit)
Emergency stop (with out-
put stage inhibit)
Inhibit output stage
Encoder – fault Here you can set the device re-
sponse to an encoder fault.
8622.14
Application stop (with out-
put stage inhibit)
Emergency stop (with out-
put stage inhibit)
Inhibit output stage
Application heartbeat
timeout
(only with DSI designs)
Here you can set the device re-
sponse to a timeout of the applica-
tion heartbeat.
8622.21
Warning
Application stop (with out-
put stage inhibit)
Emergency stop (with out-
put stage inhibit)
Inhibit output stage
8.5 Resetting fault messages
WARNING
Eliminating the cause of the problem or performing a reset may result in the drive re-
starting automatically.
Severe or fatal injuries.
Prevent unintended startup.
Acknowledge fault message by:
Switch the supply system off and on again.
Via the controller/PLC: Send "reset command".
25891936/EN – 05/2020

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SEW-Eurodrive MOVIMOT advanced DRN DBC Series and is the answer not in the manual?

SEW-Eurodrive MOVIMOT advanced DRN DBC Series Specifications

General IconGeneral
BrandSEW-Eurodrive
ModelMOVIMOT advanced DRN DBC Series
CategoryDC Drives
LanguageEnglish

Related product manuals