8
Service
Resetting fault messages
Operating Instructions – MOVIMOT
®
advanced
138
Fault Description Index
no.
Possible fault response
Encoder – warning Here you can set the device re-
sponse to an encoder warning.
8622.13
• Warning
• Application stop (with out-
put stage inhibit)
• Emergency stop (with out-
put stage inhibit)
• Inhibit output stage
Encoder – fault Here you can set the device re-
sponse to an encoder fault.
8622.14
• Application stop (with out-
put stage inhibit)
• Emergency stop (with out-
put stage inhibit)
• Inhibit output stage
Application heartbeat
timeout
(only with DSI designs)
Here you can set the device re-
sponse to a timeout of the applica-
tion heartbeat.
8622.21
• Warning
• Application stop (with out-
put stage inhibit)
• Emergency stop (with out-
put stage inhibit)
• Inhibit output stage
8.5 Resetting fault messages
WARNING
Eliminating the cause of the problem or performing a reset may result in the drive re-
starting automatically.
Severe or fatal injuries.
• Prevent unintended startup.
Acknowledge fault message by:
• Switch the supply system off and on again.
• Via the controller/PLC: Send "reset command".
25891936/EN – 05/2020