6
Startup
Startup notes
Operating Instructions – MOVIMOT
®
advanced
97
NOTICE
Undercutting the minimum switch-off time of the line contactor.
Irreparable damage to the inverter or unforeseen malfunctions.
You must observe a minimum switch-off time of 10 s after switching off the
voltage supply.
Do not switch the voltage supply on or off more often than once per minute.
INFORMATION
Before startup, remove the paint protection cap from the LED displays.
Before startup, remove the paint protection film from the nameplates.
INFORMATION
To ensure fault-free operation, do not disconnect or connect signal cables during
operation.