6
Startup
Startup notes
Operating Instructions – MOVIMOT
®
advanced
97
NOTICE
Undercutting the minimum switch-off time of the line contactor.
Irreparable damage to the inverter or unforeseen malfunctions.
• You must observe a minimum switch-off time of 10 s after switching off the
voltage supply.
• Do not switch the voltage supply on or off more often than once per minute.
INFORMATION
• Before startup, remove the paint protection cap from the LED displays.
• Before startup, remove the paint protection film from the nameplates.
INFORMATION
• To ensure fault-free operation, do not disconnect or connect signal cables during
operation.