110
Operating Instructions – Electronic Motor DRC.-..-SNI
8
Description of application option parameters
Parameters
8.5.2 GIO13B application option
Command PCB parameters \ application option \ GIO13B
Application option firmware
Application option
type index 10453.1
The parameter shows the designation of the application option inserted in the applica-
tion slot.
Application option
firmware
index 10453.16
The parameter indicates the program version of the firmware used in the application
option.
Firmware status of
application option
index 10453.17
The parameter indicates the status of the firmware used in the application option.
Application option inputs
Binary input DI10
index 9619.11,
bit 0
The parameter indicates the state and function of binary input DI10 of the application
option.
You can activate the binary inputs using DIP switch S1/2 of the application option
(activated = DIP switch set to "ON").
Binary input DI11
index 9619.11,
bit 1
The parameter indicates the state and function of binary input DI11 of the application
option.
You can activate the binary inputs using DIP switch S1/2 of the application option
(activated = DIP switch set to "ON").
Binary input DI12
index 9619.11,
bit 2
The parameter indicates the state and function of binary input DI12 on the application
option.
You can activate the binary inputs using DIP switch S1/2 of the application option
(activated = DIP switch set to "ON").
Binary input DI13
index 9619.11,
bit 3
The parameter indicates the state and function of binary input DI13 on the application
option.
You can activate the binary inputs using DIP switch S1/2 of the application option
(activated = DIP switch set to "ON").
Frequency input
LFI10
index 9619.26
LFI10 frequency input of the application option.
You can activate the frequency input using DIP switch S2/1 of the application option
(activated = DIP switch set to "ON").
The scaling is:
0Hz Ⳏ 0 digit
The maximum frequency is set to Ⳏ ± 32767 digits
The maximum frequency is set using DIP switches S2/2 to S2/4.
Track A mode: 0 – 32767 digits
Tracks A/B mode: – 32767 digits – +32767 digits
You set the mode of the frequency input using DIP switch S3/1.