Operating Instructions – Electronic Motor DRC.-..-SNI
4
Installation requirements
Mechanical Installation
4.3 Installation requirements
Check that the following conditions have been met:
The entries on the nameplate of the DRC unit match the voltage supply system.
The drive is undamaged (no damage caused by transportation or storage)
Ambient temperature according to the operating instructions, nameplate and
lubricant table in chapter "Technical data and dimension sheets / Lubricants".
The drive must not be assembled in the following ambient conditions:
Potentially-explosive atmosphere
Oils
–Acids
Gases
Vapors
Radiation
For special designs: The drive is designed in accordance with the actual ambient
conditions.
You must clean the output shafts and flange surfaces thoroughly to ensure they are
free of anti-corrosion agents, contamination or similar. Use a commercially available
solvent. Do not expose the sealing lips of the oil seals to the solvent – damage to the
material.
When the drive is installed in abrasive ambient conditions, protect the output end oil
seals against wear.

Table of Contents