Actuator status signal
Y
ou can connect the status signals from the actuator of a lock to AUX_IN of the Flexi
Loop EMSS8 node and forward them to your application.
Use IO-Link to deactivate output monitoring for all Flexi Loop nodes with a connected
lock (see "Configuration of the Flexi Loop nodes", page 58).
Use IO-Link to select the link logic of the status signals at the non-safe output of the
Flexi Loop MSTR2 accessory with the MSTR AUX_OUT LOGIC parameter (see "Configura‐
tion of the Flexi Loop string", page 60).
Connect actuator signal to the non-safe input AUX_IN of the Flexi Loop nodes. The safe
sensor cascade forwards the signal to the non-safe output on the MSTR2 Flexi-Loop
accessory. Connect this signal with your application 7.
DESIGN 4
8015836/YT10/2016-05-24 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Loop
39