2.4.11 Code 25 Family Settings
PROGRAM F_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
Code 25 Settings
SS Disable Standard/Industrial 2 of 5 0
SS Enable Standard/Industrial 2 of 5 1
SS Disable Matrix 2 of 5 2
SS Enable Matrix 2 of 5 3
SS Disable China Postal Code 4
SS Enable China Postal Code 5
SS Disable check digit verification  6
SS Enable check digit verification 7
SS Disable check digit transmission 8
SS Enable check digit transmission 9
SS Default (04)  FIN
MS 01-Maximum (2 digits)
Code 25 Family Min.
Length
Scan 2 digits from the option code chart in the Appendix;
then the scanner will terminate this selection automatically.
SS Default (98)  FIN
MS 98-Minimum (2 digits)
Code 25 Family Max.
Length
Scan 2 digits from the option code chart in the Appendix;
then the scanner will terminate this selection automatically.
For Code25 setting, we recommend you to select only one type of Code 25 or set the
maximum/minimum bar code length. To decode all types of Code 25 or to variable length of Code 25
will increase the possibility of reading error.

Table of Contents

Other manuals for SICK IDM series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK IDM series and is the answer not in the manual?

SICK IDM series Specifications

General IconGeneral
BrandSICK
ModelIDM series
CategoryBarcode Reader
LanguageEnglish

Related product manuals