User Instructions
Symbology Reading Control
IDM corded
8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice
31
2.4.13 MSI/ Plessey Settings
PROGRAM F_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
MSI/ Plessey Settings
SS Disable MSI/Plessey 0
SS Enable MSI/Plessey 1
SS Select MOD 10 check digit 2
SS Select MOD 10-10 check digit 3
SS Select MOD 11-10 check digit 4
SS Disable check digit transmission 5
SS Enable check digit transmission 6
SS Default (04) FIN
MS 01-Maximum (2 digits)
MSI/ Plessey Min. Length
Scan 2 digits from the option code chart in the Appendix;
then the scanner will terminate this selection automatically.
SS Default (98) FIN
MS 98-Minimum (2 digits)
MSI/ Plessey Max.
Length
Scan 2 digits from the option code chart in the Appendix;
then the scanner will terminate this selection automatically.