User Instructions
Operation Control (all IDM series)
IDM corded
8015906/2013-07-02 © SICK AG · Germany · All rights reserved · Subject to change without notice
67
2.10.4 Light Source On Time, Hands Free Time-out
PROGRAM F_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
SS Short 0
SS Medium 1
SS Long 2
Light Source On Time
SS Extremely long 3
SS Short 0
SS Medium 1
SS Long 2
SS Extremely long 3
Hands-free Time Out
SS Disable 4
SS Short 0
SS Medium 1
SS Long 2
SS Extremely long 3
Good Read Duration
SS Extremely short 4
SS 1 sec. 0
SS 3 sec. 1
SS 5 sec. 2
SS 7 sec. 3
SS 9 sec. 4
Time Delay to Low Power
Mode
SS Immediate 5
Light Source On Time
This function is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level
Mode. The scanner keeps the light source on till the pre-defined light source on time is up.
Hands-free Time Out
The Presentation Mode, Force Mode and Flash Mode are referred to as “Hands-free” mode. The Hands-free
mode will be automatically changed to manual trigger mode when you press the trigger. You can remain the
scanner in manual trigger mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there
isn’t any trigger operation), the imager will revert to the original hands free mode.
Time Delay to Low Power Mode
This function sets the time for the scanner to enter low power mode after any scanning activity. This setting is
only available if the scanner is in low power mode.