8012238/YY30/2015-02-20 © SICK AG • Subject to change without notice 55
Minimum Typical Maximum
Dimensions S100
Height 152 mm
Width 102 mm
Depth 105 mm
Total weight (without connecting cables) 1.2 kg
Functional data
S100 switching field 10 m
Resolution See Fig. 30 on page 52.
Configurable resolution 30, 40, 50, 70, 150 mm
Scanning range at 30 mm resolution 1.30 m
Scanning range at 40 mm resolution 1.70 m
Scanning range at 50 mm resolution 2.10 m
Scanning range at 70 mm resolution 3.00 m
Scanning range at 150 mm resolution 6.60 m
Scan angle 270°
Remission at 2 m 1.8% Several
1000% (re-
flectors
4)
)
Angular resolution 0.5° 1.0°
Recommended supplement for retroreflectors
in scan plane at a distance of less than 1 m to
the switching field boundary
200 mm
Measurement error
Systematic error
Without reflectors in the measurement
area
±15 mm
With reflectors in the measurement area ±30 mm
Statistical error (at 21 °C)
at 1
±8
mm
at 5 σ ±40 mm
Evenness of the scan field at 2 m ±50 mm
Distance from mirror axis of rotation (zero
point on the X and Y axis) to the rear of the
device
55 mm
Distance between centre of the scan plane
and the bottom edge of the housing
116 mm
Distance measuring range 30 m
Number of multiple samplings
(configurable via CDS-S100)
1 16
3)
Without fixing screws and projection of cable glands with system plug mounted.
4)
Complies with Diamond Grade 3000X™ (approx. 1250 cd/lx × m²).