Operating instructions Chapter 5
S100
8012238/YY30/2015-02-20 © SICK AG • Subject to change without notice 27
Mounting
5.2.1 Direct mounting
The S100 has two threaded holes M5×8 on the rear. Using them you can mount the S100
directly on the intended mounting surface. To avoid a possible tendency to vibrate, if
necessary the reference surface on the rear can be used as the third mounting point .
During mounting, please observe the dimensional drawings (see section 12.4 Dimen-
sional drawings” on page 60).
5.2.2 Mounting with mounting kit 1a or 1b
With the aid of mounting kit 1 you can mount the S100 indirectly on the mounting surface.
The mounting kit is available as mounting kit 1a without protection device for the optics
cover and as mounting kit 1b with protection device for the optics cover.
Fig. 12: Direct mounting
Notes
M5
×
8