Reset LED Group
The Reset LED group function block allows you to reset only the stored LEDs of the functions contained in the
respective function group, while stored LEDs activated from functions in other function groups remain active.
For more information refer to chapter 3.1.10 Resetting Stored Indications of the Function Group .
Operational, Fundamental, Symmetrical Components Measurements
The operational fundamental, symmetrical components and functional measurements are always available in
the Capacitor bank function group and cannot be deleted.
Table 5-5 Operational Measured Values (True RMS) of the Function Group Capacitor Bank
Measured Values Primary Secondary % Referenced to
I
A
, I
B
, I
C
Phase currents A A Rated operating current of the primary
system
I
N
Neutral-point phase current A A Rated operating current of the primary
system
3I
0
Residual current A A Rated operating current of the primary
system
V
A
, V
B
, V
C
Phase-to-ground voltages kV V Rated operating voltage of the primary
system/√3
V
AB
, V
BC
, V
CA
Phase-to-phase voltage kV V Rated operating voltage of the primary
system
V
0
Zero-sequence voltage kV V Rated operating voltage of the primary
system/√3
V
NG
Neutral-point displacement
voltage
kV V Rated operating voltage of the primary
system/√3
f Frequency Hz Hz Rated frequency
P
tot
Active power (total power) MW Rated operating voltage and rated oper-
ating current of the primary system
√3 · V
rated
· I
rated
Q
tot
Reactive power (total power) MVAr Rated operating voltage and rated oper-
ating current of the primary system
√3 ·V
rated
· I
rated
S
tot
Apparent power (total power) MVA Rated operating voltage and rated oper-
ating current of the primary system
√3 ·V
rated
· I
rated
Cos φ Active factor (abs) (abs) 100 % corresponds to cos φ = 1
P
A
, P
B
, P
C
Phase-related active power MW Apparent power of the phase V
rated Lx
·
I
rated Lx
Q
A
, Q
B
, Q
C
Phase-related reactive power MVAr Apparent power of the phase V
rated Lx
·
I
rated Lx
S
A
, S
B
, S
C
Phase-related apparent power MVA Apparent power of the phase V
rated Lx
·
I
rated Lx
Table 5-6 Fundamental and Symmetrical Components Measurement Values of the Function Group
Capacitor Bank
Measured Values Primary Secondary % Referenced to
I
A
, I
B
, I
C
Phase currents A A Rated operating current of the primary
system
Function-Group Types
5.4 Function-Group Type Capacitor Bank
SIPROTEC 5, Overcurrent Protection, Manual 219
C53000-G5040-C017-8, Edition 07.2017

Table of Contents

Related product manuals