Connection to PROFINET IO
7.5 Structure of the data records
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
169
LineDelay.FormatIndicator = 1
Value (hexadecimal)
Meaning
0x00000000
Reserved
0x00000001 0x7FFFFFFF Cable delay in nanoseconds.
PeerMACAddress
MAC address of the neighboring device.
MAUType
Value (hexadecimal)
Meaning
0x0000 0x0004
Reserved
0x0005 10BASET
0x0006-0x0009
Reserved
0x000A 10BASETXHD
0x000B
10BASETXFD
0x000C
10BASEFLHD
0x000D
10BASEFLFD
0x000F
100BASETXHD
0x0010
100BASETXFD (default)
0x0011
100BASEFXHD
0x0012
100BASEFXFD
0x0013 0x0014
Reserved
0x0015
1000BASEXHD
0x0016
1000BASEXFD
0x0017
1000BASELXHD
0x0018
1000BASELXFD
0x0019
1000BASESXHD
0x001A
1000BASESXFD
0x001B 0x001C
Reserved
0x001D
1000BASETHD
0x001E 1000BASETFD
0x001F
10GigBASEFX
0x0020 0x002D Reserved
0x002E
100BASELX10
0x002F 0x0035
Reserved
0x0036
100BASEPXFD
0x0037 0xFFFF
Reserved