Menus in the WBM
5.1 The System menu
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
55
TFTP Server IP Port
The port of the TFTP server over which data exchange will be handled. If necessary, you
can change the default value 69 to your own requirements using the CLI.
Configuration File
Name and possibly also folder path of the configuration file (maximum 32 characters) that
you want to load on the IE Switch X-200 or where you want to store the current configuration
information.
Note
When a
configuration file is downloaded, the device type is not checked.
Event Log File
By clicking "Save", you can save the event table (event log file) on the local computer.
Firmware File
Name and possibly also folder path of the file (maximum 32 characters) from which you want
to load the new firmware.
Note
Compatibility of the firmware versions
If you load firmware that is older than the firmware on the device, you will have to reset
the
device to the factory defaults after loading the firmware.
If you update the firmware of an IE Switch X
-200, make sure that the firmware in use is
compatible with the relevant device.
If incompatible firmware is downloaded to the device, it will no lo
nger be possible to operate
the device. In this case, compatible firmware will have to be loaded again with the boot
loader.
Firmware compatibility
Note the following restrictions relating to the compatibility of the firmware versions with the
individual devices:
Firmware version
IE switch
at least X-200IRT V4.5
X201-3P IRT PRO
at least X-200IRT V4.1
XF204IRT
at least X-200IRT V3.1 X202-2P IRT PRO
X204IRT PRO
at least X-200IRT V2.1 X200-4P IRT
X201-3P IRT
X202-2P IRT
at least X-200 V4.5 X208PRO