Menus in the WBM
5.1 The System menu
SCALANCE X-200
Configuration Manual, 03/2015, C79000-G8976-C285-06
65
NOT PRESENT
There is no C-PLUG inserted in the IE Switch X-200.
EMPTY
The inserted C-PLUG is empty.
C-PLUG Device Group
Indicates the SIMATIC NET product line that saved the current configuration on the C-PLUG.
C-PLUG Device Type
Indicates the device type within the product line that saved the current configuration on the
C-PLUG.
Configuration Revision
Indicates the version of the configuration structure. This information relates to the
configuration options supported by the IE Switch X-200. This does not relate to the actual
hardware configuration. The information can change if you update the firmware.
File System
Shows the type of C-PLUG file system.
File System Size
Shows the maximum storage capacity of the C-PLUG file system.
File System Usage
Shows the storage space being utilized in the C-PLUG file system.
C-PLUG Info String
Displays information on the device that saved the current configuration on the C-PLUG, for
example order number, type designation, version of hardware and software.
The version relates to the versions that were used on the device when the configuration was
saved on C-PLUG. The version changes if you save parameters using a different version. A
firmware update or restart of the device does not change the version.
Note
If an empty C
-PLUG in is inserted in an IE Switch X-200, the next time the device starts up,
the configuration stored internally on the basic device is transferred to the C
-PLUG.
If you operated an IE Switch X
-200 with a C-PLUG inserted, the configuration stored
internally on the basic device is no longer modified.
During ongoing operation, changes to the configuration data are stored only on the C
-PLUG.
If you remove the C
-PLUG later, the configuration stored internally on the basic device
becomes valid a
gain. This restores the configuration status prior to inserting the C-PLUG.