9 Operation at Use of a PC
9.3 Configuration of the Device
225SICAM Q100, 7KG95xx, Device Manual
E50417-H1040-C522-A6, Edition 06.2019
1)
Use the template value shown as default in the Topic name for the connection with MindSphere. The parts
in curly brackets are filled internally at startup.
2)
Refer to the manual OPC UA PubSub (MQTT) Data Points to identify the individual data points.
✧ Enter the desired values into the fields and select the corresponding parameters in the list boxes as
described in Table 9-25.
In the Data transmission section, you can select whether the data groups are transmitted via the OPC
UA PubSub (MQTT) or not. The following data are always transmitted:
Indications
operational measured values
flicker, security counters
the asset information files
✧ After the parameterization click Send.
The parameters are transmitted to the device but not enabled yet (passive set of parameters).
✧ If you do not want to make any additional settings, continue with the Activation of the device configuration
according to section Activating the Set of Parameters. If you want to change other settings, enter the
changes and then enable the device configuration as described in section Activating the Set of
Parameters.
Upload Certificates
You can click Upload certificates to upload the keys and certificates which are needed to establish a secure
Harmonics power
2)
yes yes
no
Energy counters
2)
yes yes
no
Energy counters transmit cycle 1 min 1 min to 1440 min
Parameter Default Setting Setting Range