6.3.3.3 Stop
Description
Writing trace points is ended with menu command "Stop". Since writing the trace points
influences the performance, trace should really be switched off for normal operation.
Note
End ApDiag
When ending ApDiag or when changing a project, the trace is ended.
6.3.3.4 OnFile
Description
Dialog "OnFile" can be used to convert diagnostics information (e.g. OnErrorExecute, printf)
into a text file. All settings are stored in the registry and are retained after a restart as well.
Since
converting the diagnostics information influences the performance and the settings made
here are retained after restarting WinCC or the computer, you can use option "NothingInFile"
to centrally stop writing the diagnostics information to a file.
WinCC diagnosis
6.3 ApDiag Menu Commands
WinCC: General information and installation
System Manual, 02/2017, A5E40840020-AA 169