Technical specifications
A.2 S7-200 SMART CPUs
S7-200 SMART
706 System Manual, V2.3, 07/2017, A5E03822230-AF
Table A- 42 Communication
Number of ports Ethernet: 1
Serial ports: 1 (RS485)
Add-on serial ports: 1 (with
optional RS232/485 signal
Ethernet: 1
Serial ports: 1 (RS485)
Add-on serial ports: 1 (with
optional RS232/485 signal
Ethernet: 0
Serial ports: 1 (RS485)
Add-on serial ports: 0
HMI device Ethernet: 8 connections
Serial ports: 4 connections
Ethernet: 8 connections
Serial ports: 4 connections
Ethernet: Not available
Serial ports: 4 connections
Programming device (PG) Ethernet: 1 connection
Serial ports: 1 connection
Ethernet: 1 connection
Serial ports: 1 connection
Ethernet: Not available
Serial ports: 1 connection
CPUs (PUT/GET) Ethernet: 8 client and 8 server
Ethernet: 8 client and 8 server
connections
Ethernet: Not available
Open user communication Ethernet: 8 active and 8 pas-
Ethernet: 8 active and 8 pas-
Ethernet: Not available
Data rates Ethernet: 10/100 Mb/s
RS485 system protocols:
9600, 19200, and 187500 b/s
RS485 freeport: 1200 to
Ethernet: 10/100 Mb/s
RS485 system protocols:
9600, 19200, and 187500 b/s
RS485 freeport: 1200 to
Ethernet: Not available
RS485 system protocols:
9600, 19200, and 187500 b/s
RS485 freeport: 1200 to
Isolation (external signal
to PLC logic)
Ethernet: Transformer isolat-
ed, 1500 V AC
Ethernet: Transformer isolat-
ed, 1500 V AC
Ethernet: Not available
RS485: none
Cable type Ethernet: CAT5e shielded
RS485: PROFIBUS network
Ethernet: CAT5e shielded
RS485: PROFIBUS network
Ethernet: Not available
RS485: PROFIBUS network