3 System Messages
281Digital Fault Recorder, SIMEAS R-PMU, Manual
E50417-H1076-C360-A5, Release 10.2012
291 2 SYSTEM Restart cause: File system cannot be
initialized
Flash disk fault; Hotline
292 2 SYSTEM Restart cause: Log recorder cannot be
initialized. Time stamp:
Flash disk fault; Hotline
293 2 SYSTEM Restart cause: Folder tree structure cannot
be initialized. Time stamp:
Flash disk fault; Hotline
294 2 SYSTEM Restart cause: Battery fault.
Time stamp:
Replace battery pack
295 2 SYSTEM Restart cause: Fault in log recorder queue.
Time stamp:
Hotline
296 2 SYSTEM Restart cause: Log recorder cannot be
opened. Time stamp:
Hotline
297 2 SYSTEM Restart cause: Invalid log recorder format.
Time stamp:
Hotline
298 2 SYSTEM Critical system fault: Task suspended.
Task no.:
Hotline
299 2 SYSTEM Critical system fault: Recorder task
suspended. Task no.:
Hotline
300 0 SYSTEM Self-monitoring: DAU fault DAU hardware/software fault; Hotline
384 0 BOOT Mismatch fault: DAU found but not
configured
All plugged in DAUs must be
parameterized. DAUs not needed can be
deactivated.
386 1 BOOT Fault: DAU configured but not plugged in Parameterized DAUs must be plugged in
387 0 BOOT Fault booting the DAU Hotline
388 1 BOOT Mismatch fault: Incorrect DAU configured Wrong DAU type parameterized
389 0 BOOT Fault configuring the DAU Several possible reasons: DAU and CPU
software version do not match, firmware
update recommended; DAU hardware error;
contact hotline if necessary
390 0 BOOT Fault setting the DAU time Hotline
393 0 BOOT Fault starting DAU Hotline, DAU hardware error
395 2 BOOT DAU type slot 1 -
396 2 BOOT DAU type slot 2 -
397 2 BOOT DAU type slot 3 -
398 2 BOOT DAU type slot 4 -
399 2 BOOT Device booting with firmware version: -
400 0 BOOT Fault booting the communication processor.
Internal fault number:
Hotline, CPU or DAU hardware fault
401 1 BOOT DAU deactivated -
402 1 BOOT Initialization finished Possibly an error message after an
upgrade; otherwise hotline
(consider additional texts)
403 1 BOOT DAU calibration frequency 16.66 Hz, type
not supported
SIMEAS R-PMU supports 50 Hz and 60 Hz
DAU types only.
Nevertheless, the device is ready for work
generating wrong measured values.
404 1 BOOT Wrong DAU calibration frequency of 50 Hz
for 60 Hz system
Only 60 Hz DAU types are allowed for
60 Hz nominal frequency.
Nevertheless, the device is ready for work
generating wrong measured values.
405 1 BOOT Wrong DAU calibration frequency of 60 Hz
for 50 Hz system
Only 50 Hz DAU types are allowed for
50 Hz nominal frequency.
Nevertheless, the device is ready for work
generating wrong measured values.
406 1 BOOT Unknown DAU calibration frequency Hotline, DAU hardware fault
Log No. Type Class Description Comment

Table of Contents

Other manuals for Siemens SIMEAS R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMEAS R and is the answer not in the manual?

Siemens SIMEAS R Specifications

General IconGeneral
BrandSiemens
ModelSIMEAS R
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals