EasyManua.ls Logo

Siemens SIMODRIVE 611 digital - Page 123

Siemens SIMODRIVE 611 digital
436 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
05.01
5.2 ”SIMODRIVE 611 universal HRS” control board
5-123
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
S Resolvers
Table 5-13 Encoder signal input of motor encoder X411, X412 (resolver)
Pin X411 (axis 1)
X412 (axis 2)
Function
1 Reserved, do not use
2 M Ground
3 AP Resolver, sinusoidal
4 AN Resolver, sinusoidal, inverted
5 M Inner shield ground
6 BP Resolver, cosine
7 BN Resolver, cosines, inverted
8 M Inner shield ground
9 EXC_POS Resolver excitation (pos.)
10 Reserved for test purposes, do not use
11 EXC_NEG Resolver excitation (neg.)
12 Reserved for test purposes, do not use
13 THMOTP KTY 84 (+) temperature sensor
14 Reserved, do not use
15 Reserved for test purposes, do not use
16 Reserved, do not use
17 Reserved, do not use
18 Reserved, do not use
19 Reserved, do not use
20 Reserved, do not use
21 Reserved, do not use
22 Reserved, do not use
23 Reserved, do not use
24 M Inner shield ground
25 THMOTCOM KTY 84 (–) temperature sensor
Note:
The inputs on the control must not be assigned any signals other than the intended sig-
nals. Otherwise, sporadic or permanent malfunctions can occur.