6
05.01
6.2 Function overview and settings
6-157
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
Combinations of the components:
Table 6-1 Combinations (regenerative feedback into the line supply)
I/R
16 kW
I/R
36 kW
I/R
55 kW
I/R
80 kW
I/R
120 kW
For internal
Cooling:
For internal
Cooling:
For internal
Cooling:
For internal
Cooling:
For internal
Cooling:
6SN1145–
1BA01–0BAV
6SN1145–
1BA02–0CAV
6SN1145–
1BA01–0DAV
6SN1145–
1BB00–0EAV
6SN1145–
1BB00–0FAV
For external
Cooling:
For external
cooling:
For external
cooling:
For external
Cooling:
For external
cooling:
6SN1146–
1BB01–0BAV
6SN1146–
1BB02–0CAV
6SN1146–
1BB00–0DAV
6SN1146–
1BB00–0EAV
6SN1146–
1BB00–0FAV
HFD reactor
16 kW
HFD reactor
36 kW
HFD reactor
55 kW
HFD reactor
80 kW
HFD reactor
120 kW
6SL3000–
0DE21–6AAV
6SL3000–
0DE23–6AAV
6SL3000–
0DE25–5AAV
6SL3000–
0DE28–0AAV
6SL3000–
0DE31–2AAV
Wideband
Line Filter
16 kW
Wideband
Line Filter
36 kW
Wideband
Line Filter
55 kW
Wideband
Line Filter
80 kW
Wideband
Line Filter
120 kW
6SL3000–
0BE21–6AAV
6SL3000–
0BE23–6AAV
6SL3000–
0BE25–5AAV
6SL3000–
0BE28–0AAV
6SL3000–
0BE31–2AAV
Basic
Line Filter
16 kW
Basic
Line Filter
36 kW
Basic
Line Filter
55 kW
Basic
Line Filter
80 kW
Basic
Line Filter
120 kW
6SL3000–
0BE21–6DAV
6SL3000–
0BE23–6DAV
6SL3000–
0BE25–5DAV
6SL3000–
0BE28–0DAV
6SL3000–
0BE31–2DAV
Caution
For all of the combinations not listed here (discontinued filter modules
6SN11 11–0AA01–0VAV) only the squarewave current operation
setting is
permissible.
For other operating modes, it is possible that the system will be thermally
overloaded.
Table 6-2 Power factor
Module Operation on the line side
Factor cos ϕ
Factor λ
I/R
Sinusoidal current operation cos ϕ 0.98 λ 0.97
I/R
Squarewave current operation cos ϕ 0.98 λ 0.89
UE –
cos ϕ 0.87 λ 0.67
cos ϕ: The power factor only contains the basic fundamental
λ: The power factor contains the basic fundamental and harmonic components
6 Infeed Modules11.0505.08