6
05.01
6.2 Function overview and settings
6-156
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
This function is only applicable in conjunction with I/R modules
Order No.: 6SN114V–1BV0V–0VA1
OFF: regulated infeed active (default setting)
ON: Unregulated operation in the infeed direction V
DC
link
= V
line
1.35
Notice:
For unregulated operation of the I/R units with V
line
= 400 V/415 V, the power
must be reduced (derated) as specified in Section 4.5.
OFF: Squarewave current operation (current with a squarewave shape is
drawn from the line supply)
ON: This function is only applicable in conjunction with I/R modules with
Order No.: 6SN114V–1BV0V–0VA1
sinusoidal current operation (sinusoidal current is taken from the line supply)
Note
The total length of the power cables (motor supply cables and DC link cables)
may not exceed 350 m for sinusoidal current operation and 500 m for
squarewave current operation.
Switch S1.5
Switch S1.6
6 Infeed Modules 11.0502.07