6
05.01
6.3 Technical data
6-159
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
Table 6-3 Technical specifications, I/R modules
Internal cooling
External cooling
Hose cooling
6SN11 45-
6SN11 46-
6SN11 45-
1BA0V-0BAV
1BB0V-0BAV
-
1BA0V-0CAV
1BB0V-0CAV
-
1BA0V-0DAV
1BB0V-0DAV
1BB0V-0DAV
1BB0V-0EAV
1BB0V-0EAV
1BB0V-0EAV
1BB0V-0FAV
1BB0V-0FAV
1BB0V-0FAV
Infeed/regenerative feed-
back
Rated power (S1)
S6 power
Peak power (400 V)
kW
kW
kW
16
21
35
36
47
70
55
71
91
3)
80
104
131
3)
120
156
175
Power reduction for undervoltage (calculated)
Rated power at 323 V
S6 power at 323 V
Peak power (323 V) si-
nusoidal current
Peak power (323 V)
squarewave current
kW
kW
kW
kW
14
19
30
34
32
42
60
68
50
64
74
85
72
93
112
127
108
140
149
169
Sinusoidal operation in-
put currents (AC
RMS
)
Use for dimensioning the installation, not for calculating the power!
Rated current (400 V) A
rms
27 60.5 92.5 134 202
Squarewave operation
input currents (AC
RMS
)
Use for dimensioning the installation, not for calculating the power!
Rated current (400 V) A
rms
30 67 102 149 223
Use for dimensioning the installation, not for calculating the power! (calculated)
Rated current (400 V)
unregulated operation
A
rms
33 74 114 165 248
Connection data
Voltage (power) V
rms
refer to Chapter 6.3.1, Table 6-5
Voltage (electronics) V refer to Chapter 6.3.1, Table 6-5
Power supply V
rms
At the DC link with 600/625/680 V DC or supplied in parallel, AC and DC con-
nection or DC connection only.
Frequency Hz 50 to 60 10%
Connection cross–sec-
tion
mm
2
Max. 16 Max. 50 Max. 95 Max. 95 Max. 150
Output voltage V regulated: 600/625; unregulated: 490...680 (line supply–dependent)
Module width mm 100 200 300 300 300
Type of cooling
Internal cooling
(volumetric flow rate) m
3
/h
Fan
56
Fan
2x56
Fan
2x51
Built–on fan
1)
Built–on fan
1)
External cooling
2)
Fan Fan
Mounting frame with fan assembly and
built–on fan
1)
Hose cooling
Kit for hose cooling with fan
1)
Losses
Internal cooling
External cooling
Hose cooling
W
W (int./
ext.)
W (int./
ext.)
320
50/270
585
50/535
745
115/630
115/630
1280
190/1090
190/1090
1950
290/1660
290/1660
Efficiency η 0.97 0.97 0.97 0.97 0.97
Weight
Internal cooling
External cooling
Hose cooling
kg
kg
kg
10.5
10.5
15.5
15.5
26
26
26
26
26
26
29
29
29
1) Order No. 6SN1162–0BA02–0AA2 (must be ordered separately)
2) For a module width of 300 mm with external cooling, mounting frames are required that must be ordered separately.
The fan assembly required to mount the built–on fan is included in the scope of supply of the mounting frame.
The built–on fan must be ordered separately! Mounting frames are also available for smaller module widths. However,
these are not required if openings are cut out in the rear cabinet panel for the module heatsinks as shown in this
Configuration Manual.
3) External power supply for main contactor control required (see Chapter 8.2.2).
6 Infeed Modules11.0505.08