EasyManua.ls Logo

Siemens SIMODRIVE 611 digital - Page 225

Siemens SIMODRIVE 611 digital
436 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
05.01
7.4 Line filters for I/R and UI modules
7-225
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) -- 05/2008 Edition
Caution
The connections/terminals may not be interchanged:
S Incoming line supply cable to LINE/NETZ L1, L2, L3
S Outgoing cable to the line reactor to LOAD/LAST U, V, W
If this is not observed, the line filter could be damaged.
Table 7-12 Assigning the wideband filters to the I/R modules
I/RF module
16/21 kW
I/RF module
36/47 kW
I/RF module
55/71 kW
I/RF module
80/104 kW
I/RF module
120/156 kW
Filter
components
Line filter
16 kW
Line filter
36 kW
Line filter
55 kW
Line filter
80 kW
Line filter
120 kW
Rated AC current 30 A 67 A 103 A 150 A 225 A
Supply voltage 3--ph. 380 V -- 10% ... 3--ph. 480 V AC + 10% (TN line supply)
1)
; 50...60 Hz ±10%
Order number 6SL3000--
0BE21--6AAV
6SL3000--
0BE23--6AAV
6SL3000--
0BE25--5AAV
6SL3000--
0BE28--0AAV
6SL3000--
0BE31--2AAV
Mounting position W all or base/floor mounting, refer to Fig. 7-12
Dimensions (W x H x D),
approx.
130x480x150 130x480x245 130x480x260 200x480x260 300x480x260
Module width Refer to dimension drawings, Chapter 12
Weight, filter 9kg 16 kg 19 kg 22 kg 32 kg
Power loss 70 W 90 W 110 W 150 W 200 W
Connection 16/10 mm
23)
/1.5 Nm
PE, M5 studs/3
Nm
2)
50 mm
2
/6 Nm
PE, M8
studs/13 Nm
2)
50 mm
2
/6 Nm
PE, M8
studs/13 Nm
2)
95 mm
2
/15 Nm
PE, M8
studs/13 Nm
2)
Connection strap
:
d=11mm
(M10/25 Nm)
5)
PE, M8 studs/13
Nm
2)
Terminals
Line supply connection
(line)
L1, L2, L3, PE L1, L2, L3, PE L1, L2, L3, PE L1, L2, L3, PE L1, L2, L3, PE
Terminals
Load connection (load)
U, V, W U, V, W U, V, W U, V, W U, V, W
I
rated
fuse
4)
35 A 80 A 125 A 160 A 250 A
Permissible
ambient temperature
S Operation [°C]
S Storage/transport [°C]
0 ... +40; maximum +55 at 0.6 P
rated
of the l/R module
--25 ... +70
Cooler Natural ventilation
Degree of protection to EN
60529 (IEC 60529)
IP20
EN 5501 1 radio interfer-
ence suppression
Limit value Class A for cable--borne interference if systems are engineered according to
the Configuration Manual
Limit value Class B for cable--borne faults and disturbances on request
1) The permissible supply voltage of the system depends on the infeed module used.
2) For ring cable lugs to DIN 46234.
3) The first data applies for pin--type cable lugs, the second data applies for finely--stranded conductors without end sleeves
4) The fuse used must have this rated current. Recommendations for the fuses, refer to Table 7-4.
5) Note: No shock--hazard protection (IP00)