1) With mounted fan or hose cooling.
05.01
1.3 Engineering a drive
1-37
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
Table 1-5 Engineering table for drive modules with SIMODRIVE 611 universal HRS/universal E HRS
SIMODRIVE 6SN11 Assessment factors
power modules, type
SIMODRIVE 611 universal HRS SIMODRIVE 611 universal E HRS
DC link
capaci
Resolver Encoder with 1 Vpp Encoder with 1Vpp
capaciĆ
tance
6SN1118Ă-Ă 6SN1118Ă-Ă
-Ă.NJ01
1-axis
-Ă.NK01
2-axis
-Ă.NH01
2-axis
-Ă.NH11
2-axis
mF
1–axis version
6SN11 2.x - 1AA00 - 0HA1 EP 1.1
AP 1.7
EP 1.4
AP 2.0
EP 1.5
AP 2.0
EP 1.5
AP 2.6
75
6SN11 2 . - 1AA00 - 0AA1 EP 1.1
AP 1.7
EP 1.4
AP 2.0
EP 1.5
AP 2.0
EP 1.5
AP 2.6
75
6SN11 2 . - 1AA00 - 0BA1 EP 1.1
AP 1.7
EP 1.4
AP 2.0
EP 1.6
AP 2.0
EP 1.6
AP 2.6
110
6SN11 2 . - 1AA00 - 0CA1 EP 1.1
AP 1.7
EP 1.4
AP 2.0
EP 1.6
AP 2.0
EP 1.6
AP 2.6
330
6SN11 2 . - 1AA00 - 0DA1 EP 1.2
AP 1.7
EP 1.4
AP 2.0
EP 1.7
AP 2.0
EP 1.7
AP 2.6
495
6SN11 2 . - 1AA00 - 0LA1 EP 1.7
AP 1.8
EP 1.7
AP 2.1
EP 1.7
AP 2.1
EP 1.7
AP 2.7
990
6SN11 2 . - 1AA00 - 0EA1 EP 2.7
AP 1.8
EP 2.7
AP 2.1
EP 2.7
AP 2.1
EP 2.7
AP 2.7
990
6SN11 2 . - 1AA01 - 0FA1 EP 2.7
AP 1.9
EP 2.7
AP 2.1
EP 2.7
AP 2.1
EP 2.7
AP 2.7
2145
6SN11 2 . - 1AA00 - 0JA1
1)
EP 1.3
AP 1.9
EP 1.5
AP 2.1
EP 1.7
AP 2.1
EP 1.7
AP 2.7
2145
6SN11 2 . - 1AA00 - 0KA1
1)
EP 1.4
AP 1.9
EP 1.6
AP 2.1
EP 1.8
AP 2.1
EP 1.8
AP 2.7
4290
6SN11 23 - 1AA02 - 0FA1
1)
EP 1.3
AP 1.9
EP 1.5
AP 2.1
EP 1.7
AP 2.1
EP 1.7
AP 2.7
2145
2–axis version
6SN11 2 . - 1AB00 - 0HA1 EP 1.3
AP 2.1
EP 1.5
AP 2.4
EP 1.6
AP 2.4
EP 1.6
AP 3.0
150
6SN11 2 . - 1AB00 - 0AA1 EP 1.4
AP 2.1
EP 1.7
AP 2.4
EP 1.7
AP 2.4
EP 1.7
AP 3.0
150
6SN11 2 . - 1AB00 - 0BA1 EP 1.6
AP 2.1
EP 1.8
AP 2.4
EP 1.8
AP 2.4
EP 1.8
AP 3.0
220
6SN11 2 . - 1AB00 - 0CA1 EP 1.7
AP 2.1
EP 1.8
AP 2.4
EP 1.8
AP 2.4
EP 1.8
AP 3.0
660
Assessment factors of individual modules for the electronics points (EP) and
gating points (AP) as well as permissible combinations of power modules and
control units.
Only combinations with entered EP and AP values are permissible.
Data referring to the assessment factors for EP and AP refer to the encoder
cable lengths that have been released.
Enter the values into Table 1Ć7.
SIMODRIVE 611 universal HRS with options
PROFIBUS DP
An additional 0.6 gating points must be taken into account
when the option is used.
Terminal module
In this case, no additional electronic/gating points have to
be taken into account.
SIMODRIVE 611 universal HRS/E HRS with options
When using EnDat absolute encoders, an additional 0.4 EP
(electronic points) must be added for each encoder.
1 Overview of the Drive S
y
stem11.0502.07
Aotewell Ltd
www.aotewell.com
Industry Automation
HongKong|UK|China
sales@aotewell.com
+86-755-8660-6182

Table of Contents