1
1) An additional 0.4 electronic points (EP) for each absolute value encoder
EnDat.
2) An additional 0.3 gating points (AP) must be taken into consideration for
each connected absolute value encoder with EnDat interface.
3) The value 5.4 is used for NCU 573.4/573.5 with link module.
4) Used onl
y
when the module is onl
y
su
p
p
lied b
y
the DC link.
05.01
1.3 Engineering a drive
1-39
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) -- 05/2008 Edition
Table 1-7 Engineering sheet to calculate the DC link power PzK
Designation Electronic points (EP) Gating points (AP) DC link capacitance
Assessment
factor,
individual
module
Num-
ber of
mod-
ules
Prod--
uct
Assessment
factor,
individual
module
Num-
ber of
mod--
ules
Prod-
uct
μF
Num--
ber of
mod--
ules
Prod-
uct
SIMODRIVE 611
UI module
I/R module
5kW/10kW
10 kW/25 kW
28 kW/50 kW
16 kW/21 kW
36 kW/47 kW
55 kW/71 kW
80 kW/131 kW
120 kW/175 kW
0.3
0.5
0.5
0.5
0.5
0.5
1
1
× 1=
--
0.5
0.5
0.5
0.5
0.5
0.75
0.75
× 1=
150
440
990
495
990
2145
2145
4290
1000
4)
× 1=
Monitoring module 0 0 1000
4)
× =
Braking module 0.2 × = 0.1 × = 75 × =
Capacitor module (central/distributed) 2.8 mF
4.1 mF
0
0
0
0
× =
=
2800
4100
× =
=
HLA module 1.2
1)
× = 1.5 × = 0
Power module with
control unit for FD/MSD
(values from Tables 1-6)
× =
=
=
=
=
=
× =
=
=
× =
=
=
=
=
=
× =
=
=
× =
=
=
=
=
=
× =
=
=
Power module with
SIMODRIVE 611 universal HRS
(values from Table 1-5)
× =
=
=
=
=
=
× =
=
=
=
=
=
× =
=
=
=
=
=
SIMODRIVE POSMO SI/CD 9A 0 0 Refer to Table 1-2
SIMODRIVE POSMO CD 18 A 0 0 Refer to Table 1-2
SINUMERIK 810D powerline
2)
including integrated power modules
CCU box 3LT with CCU 3
CCU box 2LT with CCU 3
2
2
× =
× =
4.5
4.5
× =
× =
660
220
SINUMERIK 840D powerline with 0
NCU 561.4 6FC5 356 -- 0BB12 -- 0AE0
NCU 571.4 6FC5 357 -- 0BB12 -- 0AE0
NCU 572.4 6FC5 357 -- 0BB23 -- 0AE0
NCU 573.4 6FC5 357 -- 0BB34 -- 0AE1
NCU 573.5 6FC5 357 -- 0BB35 -- 0AE0
1
1
1
2.3
2.3
× =
× =
× =
× =
× =
3.8
3.8
3.8
5 (5.4)
3)
5 (5.4)
3)
× =
× =
× =
× =
× =
Sum,
»Electronics« points
maximum value 8
EP Sum, »Gating«
points
maximum value 17
AP
Sum of the
DC link
capacitances
Maximum value, 3.5
(3)
The following applies for the unregulated 5 kW
infeed: Maximum 3.5 EP and maximum 7 AP.
However, with the 6SN1118--0AA11--0AA0
control units, maximum of 3 EP.
Maximum value