3.3 Parameterizing using the parameterizing and start–up tool SimoCom U
3-110
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
In order to go online with a drive via the PROFIBUS–DP fieldbus using
”SimoCom U”, the following prerequisites must be fulfilled:
1. ”SIMODRIVE 611 universal” control board from SW 3.1 with the fol-
lowing option module:
Optional PROFIBUS–DP2 module (with ASIC DPC31 without
PLL)
Order No. (MLFB): 6SN1114–0NB00–0AA1
or
Optional PROFIBUS–DP3 module (with ASIC DPC31 with PLL)
Order No. (MLFB): 6SN1114–0NB01–0AA0
2. ”SimoCom U” parameterizing and start–up tool from version 3.1
3. Communication boards, if connected via PROFIBUS
CP 5511 (PROFIBUS coupling via PCMCIA card)
Design:
PCMCIA card, type 2 + adapter with 9–pin SUB–D socket con-
nector to connect to PROFIBUS.
Order No. (MLFB): 6GK1551–1AA00
or
CP 5611 (PROFIBUS coupling through a short PCI card)
Design:
Short PCI card with 9–pin SUB–D socket to connect to
PROFIBUS.
Order No. (MLFB): 6GK1561–1AA00
CP 5613 (PROFIBUS coupling via short PCI card)
(from SW 4.1)
Design:
Short PCI card with 9–pin SUB–D socket to connect to
PROFIBUS,
diagnostic LEDs,
PROFIBUS controller ASPC2 StepE
Order No. (MLFB): 6GK1561–3AA00
4. SIMATIC–CPU, if connected via an MPI interface
A routing–capable SIMATIC–CPU is required for a coupling via MPI
interface.
5. S7–DOS from V5.0
This software is supplied on the CD for ”SIMODRIVE 611 universal”
(refer to Chapter 1.3).
6. Connecting cable
between CP 5511 or CP 5611 and the PROFIBUS fieldbus
or
between the MPI interface from the PG and SIMATIC CPU
Requirements
3 Parameterizing the Board