6
6.2 Positioning mode (P0700 = 3, from SW 2.1)
6-398
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The following parameters are available for ”referencing with distance–
coded measuring system” function:
P0161 Stopping at marks (from SW 8.3)
P0173 Reference point approach without reference cams
P1027 IM configuration, encoder
P1037 DM configuration encoder
P1050 IM reference mark distance for distance–coded
scales
P1051 IM reference mark distance for distance–coded
rotary encoders
P1052 DM reference mark distance for distance–coded
scales
P1053 DM reference mark distance for distance–coded
rotary encoders
P1054 IM difference for distance–coded rotary encoders
(from SW 8.3)
P1055 DM difference for distance–coded rotary encoders
(from SW 8.3)
Parameter
overview
(refer to 6.2.8 and
A.1)
6 Description of the Functions