6.4 Input/output terminals of the control board
6-525
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table 6-49 List of output signals, continued
Operating
mode
Signal name, description PROFIBUS bitposn–setFct. No.
Angular incremental encoder handwheel active
(from SW 8.1)
84 – x AktSatz.13
The output signal indicates whether the angular incremental encoder handwheel function is operational.
1 signal The angular incremental encoder handwheel function is active.
0 signal The angular incremental encoder handwheel function is not active.
Angular incremental encoder handwheel evaluation,
bit 0 (from SW 8.1)
85 – x AktSatz.11
Angular incremental encoder handwheel evaluation,
bit 1 (from SW 8.1)
86 – x AktSatz.12
These 2 status signals can be used to define which angular incremental encoder handwheel evaluation
is selected via parameter P0900.
Ang. incr. enc. hdw. eval. 0 1 2 3 (corresponding to P0900[4])
Bit 0 0 1 0 1
Bit 1 0 0 1 1
Note:
The ”angular incremental encoder handwheel evaluation” function is described in Chapter 6.8.
6 Description of the Functions