6.8 Angular incremental encoder interface (X461, X462)
6-560
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
For several counter modules, encoder monitoring circuits erroneously
signal faults. This is the reason that there is a secondary module with a
lower sampling frequency which can prevent the erroneous response of
the encoder monitoring function, e.g. the SIMATIC FM 354.
Module, Order No. 6SN1118–0NH00–0AA2 (Catalog)
Angular incremental encoder sampling frequency 32 MHz
Multiple edges up to approx. 16 MHz
Useful angular incremental encoder signal, max. to approx.
350 kHz (for encoders with 2048 pulses/rev. max. 10500 RPM)
Module, Order No.[MLFB] 6SN1118–0NH00–0BA2 (alternative)
Angular incremental encoder sampling frequency 1.2 MHz
Multiple edges up to approx. 600 kHz
Useful angular incremental encoder signal, max. to approx.
200 kHz (for encoders with 2048 pulses/rev. max. 6000 RPM)
From the following module, it can be assumed that the encoder moni-
toring will no longer incorrectly respond for several counter modules.
Module Order No. [MLFB] 6SN1118–NH01–0AA
Angular incremental encoder sampling frequency 4 MHz
Multiple edges up to approx. 2 MHz
Useful angular incremental encoder signal, max. to approx.
420 kHz (for encoders with 2048 pulses/rev. max. 12300 RPM)
If the angular incremental encoder interface is to be operated as set-
point input, as pulse/direction signal or as forwards/reverse signal, then
the angular incremental encoder interface of another ”SIMODRIVE 611
universal” module may not be used as setpoint source. The axis unde-
sirably traverses as a result of the multiple edges inherent to the
system.
If the angular incremental encoder interface is used as setpoint input
(pulse/direction signal or up/down signal), then a suitable setpoint
source, e.g. stepping motor control must be used with exactly the same
pulse number as master.
In order to couple to SIMODRIVE 611 universal modules, the quadra-
ture signal input signal waveform (P0894 = 0) should be used.
The following parameters must be observed when setting the angular
incremental encoder interface as output for incremental position actual
values:
P0890 Activates the angular incr. enc./encoder interface
P0892 Factor, angular incr. enc. pulse no./enc. pulse no.
P0893 Angular incremental encoder zero pulse offset
Angular
incremental
encoder interface
output for
pulse/direction
signal
Parameter
overview
(refer to Chapter
A.1)
6 Description of the Functions
01.99