6
6.9 Motor holding brake
6-571
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The following parameters are used for the ”motor holding brake” func-
tion:
P0850 Activates the brake control
P0851 Brake opening time
P0852 Speed, close holding brake (SRM, ARM)
Motor velocity, close holding brake (SLM)
P0853 Brake delay time
P0854 Controller inhibit time
Note
For controller enable:
Issuing and withdrawing the controller enable is dependent on several
internal and external enable signals (refer to Chapter 6.4.1).
For pulse enable:
Issuing and withdrawing the pulse enable is dependent on several
internal and external enable signals (refer to Chapter 6.4.1).
Parameter
overview
(refer to Chapter
A.1)
Information for
enabling the
controller and
pulses
6 Description of the Functions