7
7.3 List of faults and warnings
7-641
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
117 Target position block \%n < start of the traversing
range
Cause The target position specified in this block lies outside the absolute tra-
versing range (–200 000 000 MSR).
Remedy Change the target position in the block
Acknowledgement RESET FAULT MEMORY
Stop response STOP VI
118 Target position block \%n < end of the traversing range
Cause The target position specified in this block lies outside the absolute tra-
versing range (200 000 000 MSR).
Remedy Change the target position in the block
Acknowledgement RESET FAULT MEMORY
Stop response STOP VI
119 PLUS software limit switch actuated
Cause For a block with the ENDLOS_POS command, the axis has actuated
the plus software limit switch (P0316) for absolute or relative position-
ing.
The behavior for software limit switch reached, can be set using
P0118.0.
Remedy – Acknowledge fault
– Move away in the negative direction, jog mode
Acknowledgement RESET FAULT MEMORY
Stop response STOP V
120 MINUS software limit switch actuated
Cause For a block with the ENDLOS_NEG command, the axis has actuated
the minus software limit switch (P0315) for absolute or relative position-
ing
The behavior for software limit switch reached, can be set using
P0118.0.
Remedy – Acknowledge fault
– Move away in the positive direction, jog mode
Acknowledgement RESET FAULT MEMORY
Stop response STOP V
121 Jog 1, jog 2 or handwheel simultaneously active
Cause The input signals ”jog 1”, ”jog 2” or ”activate handwheel” were simulta-
neously activated.
Remedy – Reset both input signals
– Acknowledge the fault
– Activate the required input signal
Acknowledgement RESET FAULT MEMORY
Stop response STOP II
7 Fault Handling/Diagnostics
04.05