7
7.3 List of faults and warnings
7-645
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
135 Standstill monitoring has responded
Cause The drive has left the standstill window (P0326) after the standstill mon-
itoring time (P0325) has expired.
Possible causes are:
– Position actual value inversion (P0231) incorrectly set
– Standstill monitoring time (P0325) parameters too low
– Standstill window (P0326) parameters too low
– Position loop gain (P0200) too low
– Position loop gain (P0200) too high (instability/tendency to oscillate)
– Mechanical overload
– Check connecting cable motor/converter (phase missing, exchanged)
Remedy Check above parameters and correct.
Acknowledgement RESET FAULT MEMORY
Stop response STOP II
136 Conv.factor,feedforward contr.speed,parameter set
\%d,cannot be represented
Cause The conversion factor in the position controller between velocity and
speed cannot be displayed.
This factor depends on the following parameters:
– Spindle pitch (P0236), for linear axes
– Gearbox ratio (P0238:8/P0237:8).
Remedy Check the above mentioned parameters and correct.
Acknowledgement RESET FAULT MEMORY
Stop response STOP II
137 Conv.factor,pos.contr.output,parameter set \%d,cannot
be represented
Cause The conversion factor in the position controller between the following
error and the speed setpoint cannot be displayed.
This factor depends on the following parameters:
– Spindle pitch (P0236) (for linear axes)
– Gearbox ratio P0238:8/P0237:8
– Position control loop gain P0200:8
Remedy Check the above mentioned parameters and correct.
Acknowledgement RESET FAULT MEMORY
Stop response STOP II
138 Conversion factor between the motor and load too
high
Cause The conversion factor between the motor and load is greater than 2 to
the power of 24 or less than 2 to the power of –24.
Remedy Check the following parameters and correct:
P0236, P0237, P0238, P1005, P1024
Acknowledgement RESET FAULT MEMORY
Stop response STOP II (SRM, SLM) STOP I (ARM)
7 Fault Handling/Diagnostics
04.05