7
7.3 List of faults and warnings
7-653
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
177 Start-up passive referencing P179 not possible
Cause The start-up help for passive referencing determines the reference
point offset in P0162 in the slave drive. The following prerequisites
must be available:
– (permanent) position coupling exists to the master drive
– Master drive must be precisely at its reference point
– Slave drive has passed the zero mark.
Remedy – Establish a coupling at the slave drive: PosStw.4 or input terminal
function 72/73
– Reference the master drive: STW1.11 or input terminal function 65 at
the master drive
– ”Wiring” check: The requirement for passive referencing must be
transferred from the master to the slave drive:
Masterdrive: Output via ZSW1.15, QZsw.1 or output terminal function 69
Slave drive: read-in via STW1.15, QStw.1 or input terminal function 69
Acknowledgement RESET FAULT MEMORY
Stop response STOP II
180 Teach-in without reference point
Cause Teach-in only possible for a referenced axis.
Remedy Request reference axis and teach in
Acknowledgement RESET FAULT MEMORY
Stop response STOP IV
181 Teach-in block invalid
Cause The specified teach-in block is invalid.
Remedy Specify the valid and existing traversing block.
Acknowledgement RESET FAULT MEMORY
Stop response STOP IV
182 Teach-in standard block invalid
Cause The specified teach-in standard block is invalid.
Remedy Specify the valid and existing traversing block.
Acknowledgement RESET FAULT MEMORY
Stop response STOP IV
183 Teach-in block not found
Cause The specified teach-in block is not found.
Remedy Select the valid and existing traversing block.
Activate ”Automatically search for block numer” function.
Acknowledgement RESET FAULT MEMORY
Stop response STOP IV
7 Fault Handling/Diagnostics