891 PLUS software limit switch actuated coupled
Cause With the actual master drive velocity, this coupling axis will probably
reach or pass the PLUS software limit switch.
This warning is output if the coupled axis has fallen below 200% of the
braking travel up to the PLUS software limit switch.
Remedy Traverse the master drive so that this coupling axis goes into the per-
missible traversing range.
Acknowledgement not required
Stop response STOP VII
892 MINUS software limit switch actuated coupled
Cause With the actual master drive velocity, this coupling axis will probably
reach or pass the MINUS software limit switch.
This warning is output if the coupled axis has fallen below 200% of the
braking travel up to the MINUS software limit switch.
Remedy Traverse the master drive so that this coupling axis goes into the per-
missible traversing range.
Acknowledgement not required
Stop response STOP VII
893 Function 73 only effective at terminal I0.x
Cause The terminal function 73 ”Coupling on I0” is only effective at terminal
I0.x.
Remedy Assign terminal I0.x to function 73.
Acknowledgement not required
Stop response STOP VII
894 Inputs, optional TERMINAL module assigned twice
Cause The input terminals on the optional TERMINAL module can only be
used by one drive.
Remedy Check and correct P0676 (A) and P0676 (B).
Acknowledgement not required
Stop response STOP VII
895 Outputs, optional TERMINAL module assigned twice
Cause Only one drive can use the output terminals on the optional TERMINAL
module.
Remedy Check and correct P0696 (A) and P0696 (B).
Acknowledgement not required
Stop response STOP VII
7 Fault Handling/Diagnostics
04.05