A.2 Power module list
A-858
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The following signals are available for the ”i
2
t power module limit” func-
tion:
Output terminal signal ––> function number 37
(power module current not limited)
PROFIBUS status signal ––> MeldW.10
(power module current not limited)
The following parameters are available for the ”i
2
t power module limi-
ting” function:
Parameters which have to be set:
P1260 i2t limiting, limit current power module S6
P1261 i2t limiting, rated power module current
These parameters are preset to protect the power module. It
may be possible to protect the motor against continuous over-
load by reducing the parameter values.
Parameters used for diagnostics:
P1262 i2t time in limiting
P1263 actual i2t limit factor
P1264 i2t actual utilization factor (from SW 4.1)
Interrelationship between parameters:
P1262 Constant Running
P1263 100 % <100 %
P1264 <100 % 100 %
––> Limiting? No Yes
Output signals
(refer to Chapter
6.4.5 and 6.4.6)
Parameter
overview
(refer to Chapter
A.1)