The following applies for two ”identical” linear motors connected in
parallel:
The value for the individual motor is handled, as specified in column
”2 (parallel)” thus obtaining the value for the parallel circuit.
Table A-9 Parameters for unlisted motors (SLM)
Parameters
No. of motors
No. Name Units Value 1 2 (parallel)
1102 Motor code number – 3999 – –
1103 Rated motor current A(rms) I
0
2 I
0
1104 Maximum motor current A(rms) I
max
2 I
max
1113 Force constant N/A F 2 F
1114 Voltage constant Vs/m k
E
k
E
1115 Armature resistance Ω R
A
0.5 R
A
1116 Armature inductance mH L
A
0.5 L
A
1117 Motor weight kg m
M
2 m
M
1118 Motor standstill current A(rms) I
0
2 I
0
1146 Maximum motor velocity m/min v
max
v
max
1170 Pole pair width mm 2τ
p
2τ
p
1180 Lower current limit, current controller
adaptation
% % %
1181 Upper current limit, current controller
adaptation
% % %
1182 Factor, current controller adaptation % % %
1400 Rated motor velocity m/min v
0
v
0
!
Danger
It is only permissible to connect temperature sensor cables with PELV
or SELV voltage (refer to EN 60204–1 Chapter 6.4)
Parameters for
unlisted motors
(SLM)